Use KLPT for automatic condensate discharge from compressed-air filters, separators, dryers, tanks and drip legs. The catalog lists split and integrated styles, timer settings, pressure options and valve specifications.
- 01 Where KLPT is used
Use KLPT where condensate needs timed automatic discharge from compressed-air filters, separators, dryers, tanks or drip legs.
KLPT-A-16-1/2-AC220V-G - Kailing electronic drain valve
- A split type
- B integrated type
- 16: 1.6MPa
- 40: 4.0MPa custom option
- 1/2 standard
- 3/8 custom option
- DC24V
- AC110V 50/60Hz
- AC220V 50/60Hz
- custom voltage
- G
- ZG
- NPT
Where KLPT is used
Use KLPT where condensate needs timed automatic discharge from compressed-air filters, separators, dryers, tanks or drip legs.
RFQ confirmation points
Confirm split or integrated style, pressure option, port, voltage, thread, condensate load, timer range and installation location before quotation.
| Parameter | Value |
|---|---|
| Application | Filters, separators, dryers, tanks and drip legs in compressed-air systems |
| Drain method | Solid-state electronic timer matched with solenoid valve for automatic condensate discharge |
| Type | A split type; B integrated type |
| Pressure option | 16Bar standard option; 40Bar custom option appears in ordering code; valve table also lists 80Bar maximum pressure reference |
| Port option | 1/2 standard; 3/8 custom option; valve table also lists 1/4, 3/8 and 1/2 inlet/outlet sizes |
| Timer setting | Interval off time 0.5-45min and discharge on time 0.5-10s on KLPT-A table |
| Protection | IP65 and NEMA4 references |
| Seal | VITON seal is listed in the feature text |
KLPT timer specification
| Item | Catalog value | Evidence | Source pages |
|---|---|---|---|
| Interval off time | 0.5-45min | KLPT-A timer table | 60 |
| Discharge on time | 0.5-10s | KLPT-A timer table | 60 |
| Manual test | Yes, micro switch | KLPT-A timer table | 60 |
| Power supply | 24-240V AC/DC 50/60Hz; special 380VAC order; 12-380VAC/DC reference | KLPT-A timer table | 60 |
| Current consumption | 4mA Max | KLPT-A timer table | 60 |
| Ambient temperature | -40C to +60C | KLPT-A timer table | 60 |
| Protection | IP65, NEMA4 | KLPT-A timer table | 60 |
| Electrical connection | DIN 43650-A / ISO 4400 | KLPT-A timer table | 60 |
| Indicator | Power on/off LED, yellow | KLPT-A timer table | 60 |
KLPT valve specification
| Item | Catalog value | Evidence | Source pages |
|---|---|---|---|
| Valve type | 2/2 direct acting valve | KLPT-16 valve table | 60 |
| Inlet/outlet size | 1/4, 3/8, 1/2 | KLPT-16 valve table | 60 |
| Maximum pressure | 16Bar, 40Bar, 80Bar | KLPT-16 valve table | 60 |
| Ambient temperature | 2C to 55C | KLPT-16 valve table | 60 |
| Maximum medium temperature | 90C | KLPT-16 valve table | 60 |
| Valve body | Forged brass, 3.8mm orifice; full stainless valve can be specially ordered | KLPT-16 valve table | 60 |
| Insulation | H class, 200C | KLPT-16 valve table | 60 |
| Voltage | 24-230V AC/DC; special 380VAC order; 12-380VAC/DC 50/60Hz reference | KLPT-16 valve table | 60 |
| Mounting position | Any | KLPT-16 valve table | 60 |
Related KLT timer references
| Model | Catalog value | Source pages |
|---|---|---|
| KLT-R | 24-240V AC/DC, 4mA Max, -10C to +50C, IP65-EN 60529, 0.5-10s on, 0.5-45min off, DIN43650A | 163 |
| KLT-S | 24-240V AC/DC, 4mA Max, -10C to +50C, IP65-EN 60529, 0.5-10s on, 0.5-45min off, DIN43650A | 163 |
| KLT-E | 24-240V AC/DC, 4mA Max, -10C to +50C, IP65-EN 60529, extended step timer ranges, DIN43650A | 163 |
Frequently Asked Questions
- FAQ What is the difference between KLPT-A and KLPT-B?
The catalog order code lists A as split type and B as integrated type. Confirm the installation layout before selecting. - FAQ Can KLPT support higher pressure applications?
The order code lists 16 and custom 40 pressure options, while the valve table includes 16Bar, 40Bar and 80Bar references. Confirm the exact pressure requirement before quotation.
Need a quotation?
Send the model, medium, pressure, port size, body material and quantity for review.